Aberration corrected toroidal gratings
Easy coupling of flat detectors (MCP or CCD)
Flat field for direct detection with CCDs
Rapid spectral data collection
Ultra High Vacuum (UHV)
Aberration corrected toroidal gratings
Easy coupling of flat detectors (MCP or CCD)
Flat field for direct detection with CCDs
Rapid spectral data collection
Ultra High Vacuum (UHV)
· Aberration corrected toroidal gratings
· Easy coupling of flat detectors (MCP or CCD)
· Flat field for direct detection with CCDs
· Rapid spectral data collection
· Ultra High Vacuum (UHV)
Vacuum ultraviolet spectrograph collects a wide wavelength range in one acquisition. Three different diffraction gratings are available for work from about 10nm to 160nm. Each offers different spectral resolution and spectral range; they work in the soft x-ray (SXR, XUV), extreme ultraviolet (EUV), and VUV. This is a practical instrument for applications requiring rapid data collection from transient, short lived events. Examples include fusion plasmas formed in tokamak devices, laser ablation, liquid droplet EUVL sources, and Xenon plasma at 13.5nm considered for extreme ultraviolet lithography.
The flat field toroidal grating instruments works over a fixed wavelength range. The prescription of the toroid and aberration correction determines the optimum region of use. Due to intensive design and difficult optical fabrication selection of gratings is limited. If there is a grating available for your wavelength of interest, you are in luck! These instruments exhibit relatively simple opto-mechanical systems that deliver good imaging and fair spectral resolution. They also allow use of a direct detection CCD to acquire high-energy spectra. Fragile microchannel plate (MCP) intensifiers can be reserved for those systems requiring gating.
Optical Design | Toroidal Grating Flat Field Spectrograph |
Angle of Incidence | ~71 degrees |
Focal Length | 292.1 mm |
Acceptance | 24 mrad |
Wavelength Range | refer to grating of interest for range |
Grating(s) | Single, kinematic grating holder. Two grating turret optional. |
Slit | Continuously variable micrometer actuated width 0.01 to 1 mm. Settable height. |
Vacuum | Ultra High Vacuum 10E-9 torr standard |
Focal Plane | 40 mm microchannel plate or 25 mm direct detection CCD |
Grating Groove Density (g/mm) | 2105 | 450 | 290 |
Spectral Resolution (nm,FWHM) | 0.05 | 0.1 | 0.16 |
Focal Plane Width (mm) | 40 | 40 | 40 |
Wavelength Range (nm) | 9.5 to 32 | 10 to 110 | 15.5 to 170 |
Energy Range (eV) | 130 to 39 | 124 to 11 | 80 to 7 |
Modes of Operation
UHV Adjustable Entrance Slit CCD | UHV Dual Grating Turret | UHV Adjustable MCP/CCD Mount | Toroidal (or other) collection optics |
Flat field aberration corrected toroidal grating spectrometer fills a 40mm focal plane ideal for microchannel plate intensifiers. Compact and versatile most are in use in tokamak plasma research, some now for high harmonic generation and attosecond laser physics. Versions exist with dual and triple grating turrets, back-to-back diffraction gratings for simultaneous, dual-range monitoring, rocking mechanisms to scan large plasma sections and more.
For a general purpose laboratory instrument, greater flexibility, or astrophysics instrument calibration (for example) consider the Rowland circle design grazing incidence system Model 248/310G. It provides most flexibility with respect to wavelength range. Many grating choices are available and it delivers excellent spectral resolution.
Call to discuss the deatils of your application today.
Some example / test spectra
Deuterium Lyman Alpha | Helium and He II Series | Ionized Helium and Neon |
This spectra was collected with the Model 251 toroidal aberration corrected flat field grating on direct detection CCD. Source used was ionized gas hollow cathode and deuterium lamp with magnesium fluride window.
Call 1-978-256-4512 to discuss your application today.
Select Publications
Charge exchange recombination detection of low-Z and medium-Z impurities in the extreme UV using a digital lock-in technique
Abstract: More sensitive detection of charge exchange recombination lines from low-Z elements, and first-time detection from the medium-Z elements nickel and copper, has been achieved in DIII-D plasmas with a digital lock-in technique. That portion of the extreme UV spectrum varying synchronously in time with the square-wave modulation of a high energy, neutral heating beam is extracted by forming a scalar product of a correlation function with the data record of each pixel in the linear array detector. The usual, dense array of collisionally excited, metallic lines from the tokamak plasma is strongly suppressed, leaving only a sparse spectrum of lines dominated by charge exchange recombination transitions from fully stripped, low-Z elements. In plasmas with high metal content, charge exchange recombination lines from the Li-like ions of nickel and copper have been positively identified.
Brooks NH, Burrell KH, Isler RC, Meyer O, Pablant NA
Multichannel grazing-incidence spectrometer for plasma impurity diagnosis: SPRED
Abstract: A compact vacuum ultraviolet spectrometer system has been developed to provide time-resolved impurity spectra from tokamak plasmas. Two interchangeable abberation-corrected toroidal diffraction gratings with flat local fields provide simultaneous coverage over the ranges 100-1100 A or 160-1700 A. The detector is an intensified self-scanning photodiode array. Spectral resolution is 2 A with the higher dispersion grating. Minimum readout time for a full spectrum is 20 msec, but up to seven individual spectral lines can be measured with a 1-msec time resolution. The sensitivity of the system is comparable with that of a conventional grazing-incidence monochromator.
Fonck, R.J. ; Ramsey, A.T. ; Yelle, R.V.
A vacuum ulra-violet spectrometer (Double SPRED) for the observation of the JET divertor plasma
Abstract: The SPRED spectrometer is a VUV survey instrument that has been successfully employed on a number of plasma machines. Its use of a holographic grating results in a flat focal field, enabling the best spectral resolution to be achieved over the whole extent of the detector. A double SPRED spectrometer having two fixed gratings and two independently controlled detectors has been installed on the JET machine for the observation of the divertor plasma. An additional improvement over previous SPRED designs is the extended wavelength coverage of the detectors. The experimental setup, including the spectrometer design, the VUV detectors, the alignment and control systems are described. The commissioning of the spectrometer on JET has allowed the performance of the instrument to be assessed, in particular its wavelength calibration, spectral resolution, and the effect of the integral shielding to nuclear radiation-induced noise. First results include a comparison with the spectral emission from the bulk plasma of the JET tokamak, observed with a single SPRED instrument, which emphasizes that the dominant emission from the divertor originates from low ionization stages or low Z-impurities such as carbon. Evidance has been found for the localization of the line emission from within the divertor chamber and some features of the divertor VUV radiation during high performance plasmas are described. Future applications are also discussed.
R.C. Wolf, K.D. Lawson, I. Coffey, R. Giannella, C.J. Hancock, N.C. Hawkes, L.D. Horton, G. Janeschitz, H. Jemmeson, A.C. Maas, C.F. Maggi and M. Di Maio
Control of high-order harmonic emission using attosecond pulse trains
Abstract: We show that attosecond pulse trains are a natural tool to control strong field processes such as high-order harmonic generation. Coherently combining an attosecond pulse train with an IR driving field, we predict and experimentally confirm enhancement and spectral narrowing of the harmonic yield at photon energies around 90 eV. The use of an attosecond pulse train to seed the harmonic generation process replaces tunneling ionization with a single-photon ionization step, therefore permitting the manipulation of the time-frequency properties of high-order harmonic generation already at the single-atom level.
J. Biegert; A. Heinrich; C. P. Hauri; W. Kornelis; P. Schlup; M. P. Anscombe; M. B. Gaarde; K. J. Schafer; U. Keller
Spectral investigations of photoionized plasmas induced in atomic and molecular gases using nanosecond extreme ultraviolet (EUV) pulses
Abstract: In this paper, results of spectral investigations of low temperature photoionized plasmas, created by irradiation of gases with intense pulses of extreme ultraviolet (EUV) radiation from a laser-produced plasma (LPP) source, are presented. The LPP source was based on a double-stream KrXe/He gas-puff target irradiated with 4 ns/0.8 J/10 Hz Nd:YAG laser pulses. The most intense emission from the source spanned a relatively narrow spectral region λ ≈ 10–12 nm; however, spectrally integrated intensity at longer wavelengths was also significant. The EUV beam was focused on a gas stream, injected into a vacuum chamber synchronously with the EUV pulses. Irradiation of gases resulted in formation of photoionized plasmas emitting radiation in the EUV range. Radiation spectra, measured for plasmas produced in various gases, are dominated by emission lines, originating from single charged ions. Significant differences in spectral intensities and distributions between plasmas created in neon and molecular gases were observed.
A. Bartnik, H. Fiedorowicz and P. Wachulak
First tritium operation of ITER-prototype VUV spectroscopy on JET
Abstract: Results from tritium operation of the VUV survey spectrometer on the JET tokamak are presented. The instrument, located outside the biological shield and offset from a direct plasma 1-o-s for maximum radiation protection, was operational during the trace tritium campaign (TTE) at JET. No discernible increase in detector background noise levels were detected for total neutron rates of up to 1×1017/s , demonstrating the shielding effectiveness of the configuration. Some tritium retention in the detector microchannel plate was measurable, but has not hampered subsequent operations. As a reference the unshielded detector of a close-coupled XUV instrument was operated during TTE (the spectrometer itself was valved off from the JET vessel). This was exposed to neutron fluxes of ∼109/cm2 s , in excess of those predicted for the corresponding instrument on ITER (107–108/cm2 s) . A corresponding increase in the background level equivalent to ∼5% of the detector dynamic range was measured. This demonstration of the shielding effectiveness of the SPRED configuration during DT operations, coupled with the tolerable noise levels measured in the SOXMOS detector, give confidence in the planned implementation of such instruments in ITER.
I. H. Coffey, R. Barnsley
Photoionization of gases by EUV pulses from a laser-plasma source
Abstract: In this work a laser-plasma EUV source was used for photoionization of noble and molecular gases. The resulting photoelectrons excited various electronic states in neutrals and ions leading to emission of radiation in EUV/VUV range. Irradiation was performed using a full wavelength range of the source or a short wavelength part selected with a Zr filter. The corresponding spectra were recorded using a toroidal grating spectrograph. Significant differences for spectra obtained in different conditions were revealed.
A. Bartnik, P. Wachulak, H. Fiedorowicz, R. Jarocki, J. Kostecki, M. Szczurek
Versatile attosecond beamline in a two-foci configuration for simultaneous time-resolved measurements
Abstract: We present our attoline which is a versatile attosecond beamline at the Ultrafast Laser Physics Group at ETH Zurich for attosecond spectroscopy in a variety of targets. High-harmonic generation (HHG) in noble gases with an infrared (IR) driving field is employed to generate pulses in the extreme ultraviolet (XUV) spectral regime for XUV-IR cross-correlation measurements. The IR pulse driving the HHG and the pulse involved in the measurements are used in a non-collinear set-up that gives independent access to the different beams. Single attosecond pulses are generated with the polarization gating technique and temporally characterized with attosecond streaking. This attoline contains two target chambers that can be operated simultaneously. A toroidal mirror relay-images the focus from the first chamber into the second one. In the first interaction region a dedicated double-target allows for a simple change between photoelectron/photoion measurements with a time-of-flight spectrometer and transient absorption experiments. Any end station can occupy the second interaction chamber. A surface analysis chamber containing a hemispherical electron analyzer was employed to demonstrate successful operation. Simultaneous RABBITT measurements in two argon jets were recorded for this purpose.
R. Locher, M. Lucchini, J. Herrmann, M. Sabbar, M. Weger, A. Ludwig, L. Castiglioni, M. Greif, M. Hengsberger, L. Gallmann and U. Keller
Luminescence of He and Ne gases induced by EUV pulses from a laser plasma source
Abstract: In this work helium and neon photoionization experiments, using a laser-plasma EUV (extreme ultraviolet) source were performed. The EUV radiation was focused onto a gas stream, injected into a vacuum chamber synchronously with the EUV pulse. The most intense emission from the source spanned a relatively narrow spectral region centered at λ=11±1 nm, however, spectrally integrated intensity at longer wavelengths was also significant. Additionally Zr and Al filters were used to narrow the irradiation spectrum and to change the irradiation conditions. Irradiation of gases resulted in EUV luminescence, acquired by a toroidal grating spectrometer. The dominating spectral lines originate from singly charged ions, however, Ne III lines were also detected. Significant differences were observed between spectra obtained for different irradiation conditions. The differences were mainly due to various possibilities of photoexcitation of corresponding states depending on energy distribution of irradiating photons.
A. Bartnik, P. Wachulak, H. Fiedorowicz, R. Jarocki, J. Kostecki, M. Szczurek